NetBSD Problem Report #60451
From www@netbsd.org Thu Jul 16 03:56:04 2026
Return-Path: <www@netbsd.org>
Received: from mail.netbsd.org (mail.netbsd.org [199.233.217.200])
(using TLSv1.3 with cipher TLS_AES_256_GCM_SHA384 (256/256 bits)
key-exchange X25519 server-signature RSA-PSS (2048 bits)
client-signature RSA-PSS (2048 bits))
(Client CN "mail.netbsd.org", Issuer "YR2" (not verified))
by mollari.NetBSD.org (Postfix) with ESMTPS id 8D99D1A923B
for <gnats-bugs@gnats.NetBSD.org>; Thu, 16 Jul 2026 03:56:04 +0000 (UTC)
Message-Id: <20260716035603.93A1C1A923C@mollari.NetBSD.org>
Date: Thu, 16 Jul 2026 03:56:03 +0000 (UTC)
From: campbell+netbsd@mumble.net
Reply-To: campbell+netbsd@mumble.net
To: gnats-bugs@NetBSD.org
Subject: sysmon: warn of low battery before forcing reboot
X-Send-Pr-Version: www-1.0
X-From4GNATS: "campbell+netbsd@mumble.net via gnats" <gnats-admin@NetBSD.org>
>Number: 60451
>Category: kern
>Synopsis: sysmon: warn of low battery before forcing reboot
>Confidential: no
>Severity: serious
>Priority: medium
>Responsible: kern-bug-people
>State: open
>Class: sw-bug
>Submitter-Id: net
>Arrival-Date: Thu Jul 16 04:00:00 +0000 2026
>Originator: Taylor R Campbell
>Release: current, 11, 10, 9, ...
>Organization:
The WarningBatterieSD Foundation, Inc.
>Environment:
>Description:
sysmon(4) will currently deliver a `low-power' event to
powerd(8) if:
- No AC adapters are plugged in.
- All batteries are below the critical level.
powerd(8) is mandated to commence an orderly shutdown -- the
transition to sysmon_low_power state is irreversible:
https://nxr.netbsd.org/xref/src/sys/dev/sysmon/sysmon_envsys_events.c?r=1.123#1017
On past laptops, I would add a powerd(8) script for the
warning-under event to suspend my laptop, to give me some time
to plug in without losing my state. But my current laptop has
two batteries, and one might enter the warning state while the
other has plenty of juice left. Also, at boot, even if the
laptop is plugged in, sysmon(4) may send warning-under events
to powerd(8).
It would be nice if sysmon(4) could deliver a `power-warning'
event or something to powerd(8) if:
- No AC adapters are plugged in.
- All batteries are below the warning level.
>How-To-Repeat:
1. find a bug that breaks xbattbar so you stop running it
2. file a PR for that bug (TBD)
3. run out of power working on something else
>Fix:
Yes, please!